If you are looking to receive a personalized quote for the NH2-222-3297, Fastener Orbit is your sourcing solution. NH2-222-3297 manufactured by American Standard Inc and is described as a Switch Thermostatic, listed alongside the part number NH2-222-3297. This item, alongside the many other NSN parts listed on our website, is readily available for purchase at any time. When you complete the RFQ form below, we ask that you provide us all required information so that we may best create a solution that fits your particular needs and requirements.
As a leading distributor of NSN parts and components, we invite you to peruse our inventory to find all the CAGE Code 96452 parts and other American Standard Inc products that you require such as NSN 5930-01-233-3147. Adhering to strict quality control regulations and requirements, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B certification and accreditation. Furthermore, our items are all sourced from leading global manufacturers and an approved vendor list (AVL) as a part of our NO CHINA SOURCING pledge. If you have any questions regarding our offered services or would like to see how we can meet your specific needs, give our team members a call or email at your earliest convenience and they would be more than happy to assist you.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-233-3147 Item Description: Switch Thermostatic | 5930 | 012333147 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Nh2-222-3297 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT" |
ABHP | III OVERALL LENGTH | 5.188 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 8.875 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL" |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | BULB" |
AWTN | OPERATING TEMP RATING | 165.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE" |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +90.00 TO 165.00 ACTUATION POINT DEGREES FAHRENHEIT AND +88.00 TO 163.00 DEACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT" |
ABHP | III OVERALL LENGTH | 5.188 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 8.875 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL" |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | BULB" |
AWTN | OPERATING TEMP RATING | 165.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE" |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +90.00 TO 165.00 ACTUATION POINT DEGREES FAHRENHEIT AND +88.00 TO 163.00 DEACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote