If you are looking to receive a personalized quote for the 674-0008-00, Fastener Orbit is your sourcing solution. 674-0008-00 manufactured by Rockwell Collins Inc and is described as a Transformer Power, listed alongside the part number 674-0008-00. This item, alongside the many other NSN parts listed on our website, is readily available for purchase at any time. When you complete the RFQ form below, we ask that you provide us all required information so that we may best create a solution that fits your particular needs and requirements.
As a leading distributor of NSN parts and components, we invite you to peruse our inventory to find all the CAGE Code 13499 parts and other Rockwell Collins Inc products that you require such as NSN 5950-00-084-3435. Adhering to strict quality control regulations and requirements, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B certification and accreditation. Furthermore, our items are all sourced from leading global manufacturers and an approved vendor list (AVL) as a part of our NO CHINA SOURCING pledge. If you have any questions regarding our offered services or would like to see how we can meet your specific needs, give our team members a call or email at your earliest convenience and they would be more than happy to assist you.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-084-3435 Item Description: Transformer Power | 5950 | 000843435 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
674-0008-00 | C | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.937 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKW | OVERALL HEIGHT | 2.750 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 4.437 INCHES MAXIMUM" |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE" |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 2.5 KILOVOLT-AMPERE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 5.937 INCHES NOMINAL" |
ADAT | BODY WIDTH | 4.437 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | OPEN" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 418.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG" |
ABHP | OVERALL LENGTH | 5.937 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKW | OVERALL HEIGHT | 2.750 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 4.437 INCHES MAXIMUM" |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE" |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 2.5 KILOVOLT-AMPERE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 5.937 INCHES NOMINAL" |
ADAT | BODY WIDTH | 4.437 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | OPEN" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 418.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG" |